4.3.7.2 Installing the BER
• Unlock the maintaining flange (item 4) by turning the locking
mechanism key.
• Remove the maintaining flange (item 4).
• Offer up the BER (item 3) to the BER bracket (item 8 or 10) pointing the
BER connectors towards the BER bracket power supply filter (item 2).
• Insert the BER (item 3) in the bracket lugs (item 5).
• Put back the maintaining flange (item 4) and lock it in place.
• Make the following connections corresponding to the type of BER
bracket:
BER bracket – HR1348 (item 8):
♦ connect the BER bracket (item 8) Sub–D 25–pin connector
(item 7) to the Sub–D 25–pin adapter (item 6) and lock it,
♦ connect the antenna cable (item 1) to the BER antenna cable,
BER bracket – HR6237 (item 10) :
♦ connect the system cable Sub–D 25–pin connector (item 9) to
the BER Sub–D 25–pin operating connector (item 3) and lock it,
♦ connect the antenna cable (item 1) to the BER antenna cable.