4.3.7.2 Installing the BER
Unlock the maintaining flange (item 4) by turning the locking
mechanism key.
Remove the maintaining flange (item 4).
Offer up the BER (item 3) to the BER bracket (item 8 or 10) pointing the
BER connectors towards the BER bracket power supply filter (item 2).
Insert the BER (item 3) in the bracket lugs (item 5).
Put back the maintaining flange (item 4) and lock it in place.
Make the following connections corresponding to the type of BER
bracket:
BER bracket – HR1348 (item 8):
connect the BER bracket (item 8) Sub–D 25–pin connector
(item 7) to the Sub–D 25–pin adapter (item 6) and lock it,
connect the antenna cable (item 1) to the BER antenna cable,
BER bracket – HR6237 (item 10) :
connect the system cable Sub–D 25–pin connector (item 9) to
the BER Sub–D 25–pin operating connector (item 3) and lock it,
connect the antenna cable (item 1) to the BER antenna cable.