Installation Instructions

MOBILE TERMINAL INSTALLATION HANDBOOK (BER VERSION B)
E
N
G
L
I
S
H
16/32 09/2001
IH – PS8432EAE01
This document is the property of MATRA NORTEL COMMUNICATIONS and should not be copied or circulated without permission
Maximum consumption:
in transmit mode (max. power): 5 A
in receive mode: 0.5 A
Power supply filter protection:
fuse: 7.5 A
2.4.3 External interface specifications
2.4.3.1 Power supply input
DC source: between 10.8 V and 15.6 V at the end of the power supply
cable, battery side, respecting the conditions in Section 2.3.3.
2.4.3.2 Antenna output
TNC female socket
Impedance: 50
2.4.4 Environmental specifications
Operation:
Dry heat : standard IEC 68–2–2 + 55 °C, 30% RH, 16 h
Cold : standard IEC 68–2–1 20 °C, 16 h
Humid heat : standard IEC 68–2–56 + 40 °C, 95 % RH,
21 days
Storage/transport:
Dry heat : standard IEC 68–2–2 + 70°C, 30% RH,72 h
Cold : standard IEC 68–2–1 –40 °C, 72 h
Humid heat : standard IEC 68–2–30 + 25 °C, 98 % RH,
+ 55 °C, 93% RH,