Installation Instructions

MOBILE TERMINAL INSTALLATION HANDBOOK (BER VERSION B)
E
N
G
L
I
S
H
14/32 09/2001
IH – PS8432EAE01
This document is the property of MATRA NORTEL COMMUNICATIONS and should not be copied or circulated without permission
2.3.3 Power supply cable
The power supply cable must include two wide diameter conductors of at
least 1.5 mm
2
protected in a mechanical housing.
The power supply voltage drop in the cable must be under 300 mV for a
current of 3 A (transmission at 10 W).
The power supply cable must only be used for the mobile terminal power
supply.
2.3.4 External loudspeaker (optional)
The mobile terminal can use an external loudspeaker. The loudspeaker
can be supplied by the manufacturer (see Section 2.2.3) or locally.
If supplied locally, it must have the following characteristics :
power : 15 W,
impedance : 4 .
The loudspeaker cable must be an audio screened or non–screened cable
with two wires. The cable is connected to the system cable via the 2–pin
female connector included in the system cable kit.
2.3.5 User Data Terminal (optional)
The User Data Terminal (UDT) is a laptop PC.
The UDT cable must be a screened single braided cable, type RG250, for
example. The cable is connected to the system cable via an HE501 9–pin
male connector.