User manual
37
Instruction Manual
PS 8000 3U Series
EN
Date: 01-24-2012
About the device
* Related to the nominal value, the accuracy denes the maximum allowed deviation between set value and actual value.
Example: a 80V model has min. 0.2% voltage accuracy. This is 160mV. When setting a voltage of 5V and with an allowed maximum deviation of 160mV, the resulting
actual value could be between 4.84V and 5.16V.
PS 8240-170 3U PS 8500-90 3U PS 8600-70 3U PS 81500-30 3U
Mains input
Input voltage range 340…460V AC 340…460V AC 340…460V AC 340…460V AC
Input voltage range optional 588…796V AC+MP 588…796V AC+MP 588…796V AC+MP 588…796V AC+MP
Required phases L1, L2, L3, PE L1, L2, L3, PE L1, L2, L3, PE L1, L2, L3, PE
Input frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz
Input fuse 6x T16A 6x T16A 6x T16A 6x T16A
Input current max. 28A max. 28A max. 28A max. 28A
Power factor > 0.99 > 0.99 > 0.99 > 0.99
Output - Voltage
Nominal voltage U
Nom
240V 500V 600V 1500V
Adjustable range
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
Stability at mains fluctuation ±10% ∆U
IN
< 0.02% < 0.02% < 0.02% < 0.02%
Stability at 0…100% load < 0.05% < 0.05% < 0.05% < 0.05%
Ramp-up time 10...90% at 100% load max. 30ms max. 30ms max. 30ms max. 30ms
Ripple @ BWL 20MHz
< 500mVpp
< 20mVrms
< 300mVpp
< 70mVrms
< 400mVpp
< 80mVrms
< 1000mVpp
< 350mVrms
Accuracy* ≤ 0.2% ≤ 0.2% ≤ 0.2% ≤ 0.2%
Resolution of display 100mV 100mV 100mV 1V
Remote sense compensation max. 7.5V max. 10V max. 18V max. 30V
Overvoltage protection
threshold (adjustable)
0…264V 0…550V 0…660V 0…1650V
Output - Current
Nominal current I
Nom
170A 90A 70A 30A
Adjustable range
0…I
Nom
0…I
Nom
0…I
Nom
0…I
Nom
Stability at mains fluctuation ±10% ∆U
IN
< 0.05% < 0.05% < 0.05% < 0.05%
Stability at 0…100% ∆U
OUT
< 0.15% < 0.15% < 0.15% < 0.15%
Ripple @ BWL 20MHz
< 333mApp
< 27mArms
< 50mApp
< 23mArms
< 30mApp
< 12mArms
< 19mApp
< 13mArms
Accuracy* ≤ 0.2% ≤ 0.2% ≤ 0.2% ≤ 0.2%
Resolution of display 100mA 10mA 10mA 10mA
Transient recovery time 10….90% load < 2ms < 2ms < 2ms < 2ms
Output - Power
Nominal power P
Nom
15000W 15000W 15000W 15000W
Nominal power at derating
0...P
Nom
0...P
Nom
0...P
Nom
0...P
Nom
Accuracy* ≤ 2% ≤ 2% ≤ 2% ≤ 2%
Resolution of display 0.01kW 0.01kW 0.01kW 0.01kW
Efficiency 93% 95.50% 95.20% 95.50%
Miscellaneous
Ambient temperature 0….50°C 0….50°C 0….50°C 0….50°C
Storage temperature -20….70°C -20….70°C -20….70°C -20….70°C
Humidity rel. < 80% < 80% < 80% < 80%
Dimensions (WxHxD) ** 19" 3U 595mm 19" 3U 595mm 19" 3U 595mm 19" 3U 595mm
Weight 33kg 33kg 33kg 33kg
Redundancy no yes no no
Isolation +output to enclosure 500V DC 1000V DC 1000V DC 2000V DC
Isolation -output to enclosure
Isolation input to output
Cooling
Standards
Overvoltage class
Protection class
Pollution degree
Operational altitude
Series operation
max. series connection voltage
Master-Slave
Parallel operation
max. parallel connection voltage
Master-Slave
Analogue programming
Input range
Accuracy
Input impedance
Article number 09230164 09230167 09230174 09230169
≤ 0.2%
53kOhm
4200V DC
by fans, air inlet on the front, air exhaust on the rear
EN 60950, EN 61326, EN 55022 Class B
2
1
2
0…5V or 0…10V, selectable
<2000m
600V
no
1500V
yes, via Share bus