About the device
PS 8080-120 2U PS 8160-60 2U PS 8360-30 2U PS 8720-15 2U
Mains input
Input voltage range 180…264V AC 180…264V AC 180…264V AC 180…264V AC
- with derating 180...207V AC 180...207V AC 180...207V AC 180...207V AC
Input current at 230V max. 15A max. 15A max. 15A max. 15A
Input current at 100V - - - -
Input frequency 45…65Hz 45…65Hz 45…65Hz 45…65Hz
Input fuse T 16A T 16A T 16A T 16A
Power factor > 0.99 > 0.99 > 0.99 > 0.99
Output - Voltage
0 0 0 0
Nominal voltage U
Nom
80V 160V 360V 720V
Adjustable range
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
Stability at mains fluctuation ±10% ∆U
IN
< 0.02% < 0.02% < 0.02% < 0.02%
Stability at 0…100% load < 0.05% < 0.05% < 0.05% < 0.05%
Ripple @ BWL 20MHz
< 10mV
pp
< 5mV
RMS
< 20mV
pp
< 10mV
RMS
< 30mV
pp
< 12mV
RMS
< 50mV
pp
< 20mV
RMS
Accuracy* ≤ 0.2% ≤ 0.2% ≤ 0.2% ≤ 0.2%
Resolution of display 10mV 100mV 100mV 100mV
Remote sense compensation max. 2.5V max. 5V max. 8V max. 16V
Overvoltage protection
threshold (adjustable)
0….88V 0…176V 0…396V 0…792V
Output - Current
Nominal current I
Nom
120A 60A 30A 15A
Adjustable range
0…I
Nom
0…I
Nom
0…I
Nom
0…I
Nom
Stability at mains fluctuation ±10% ∆U
IN
< 0.05% < 0.05% < 0.05% < 0.05%
Stability at 0…100% ∆U
OUT
< 0.15% < 0.15% < 0.15% < 0.15%
Ripple @ BWL 20MHz
< 25mA
pp
< 9mA
RMS
< 18mA
pp
< 6mA
RMS
< 60mA
pp
< 21mA
RMS
< 2mA
pp
< 1mA
RMS
Accuracy* ≤ 0.2% ≤ 0.2% ≤ 0.2% ≤ 0.2%
Resolution of display 100mA 10mA 10mA 10mA
Transient recovery time 10….90% load < 2ms < 2ms < 2ms < 2ms
Output - Power
Nominal power P
Nom
3000W 3000W 3000W 3000W
Nominal power at derating 2500W 2500W 2500W 2500W
Accuracy*
0...P
Nom
0...P
Nom
0...P
Nom
0...P
Nom
Adjustable range ≤ 1% ≤ 1% ≤ 1% ≤ 1%
Resolution of adjustment 1W 1W 1W 1W
Efficiency max. 93.0% 93.0% 93.0% 93.0%
Miscellaneous
Ambient temperature 0….40°C 0….40°C 0….40°C 0….40°C
Storage temperature -20….70°C -20….70°C -20….70°C -20….70°C
Humidity rel. < 80% < 80% < 80% < 80%
Dimensions normal (WxHxD) 19" 2U 460mm 19" 2U 460mm 19" 2U 460mm 19" 2U 460mm
Dimensions with option ZH (WxHxD) 19" 4U 460mm 19" 4U 460mm 19" 4U 460mm -
Weight normal 14.7kg 14.7kg 14.7kg 14.7kg
Weight with option ZH 17kg 17kg 17kg -
Isolation +output<->enclosure 500V 500V 500V 1000V
Isolation -output<->enclosure
Isolation input<->output
Cooling
Standards
Overvoltage class
Protection class
Pollution degree
Operation altitude
Series connection
max. series connection voltage
Master-Slave
Parallel connection
max. parallel connection voltage
Master-Slave
Analogue programming
Input range
Accuracy
Article numbe
r
09230135 09230136 09230138 09230139
300V DC
yes, via Share bus
1
2
< 2000m
4200V
by fans, air inlets on the front, air exhaust on the rear
0…5V or 0…10V, selectable
<
0.2%
600V
no
720V
EN 60950, EN 61326, EN 55022 Class B
2
* Related to the nominal value, the accuracy denes the maximum allowed deviation between set value and actual value.
Example: a 80V model has min. 0.2% voltage accuracy. This is 160mV. When setting a voltage of 5V and with an allowed maximum deviation of 160mV, the resulting
actual value could be between 4.84V and 5.16V.