Instructions

Table Of Contents
Page 10
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
PS 2000 B Single Series
84 V
Model
PS 2084-03 B PS 2084-05 B PS 2084-10 B
AC Input
Voltage range 90...264 V AC 90...264 V AC 90...264 V AC
Connection Wall outlet Wall outlet Wall outlet
Frequency 45-65 Hz 45-65 Hz 45-65 Hz
Fusing T 2 A T 3.15 A T 6.3 A
Power factor ≈0.99 ≈0.99 ≈0.99
DC Output
Max. output voltage U
Max
84 V 84 V 84 V
Max. output current I
Max
3 A 5 A 10 A
Max. output power P
Max
100 W 160 W 320 W
Overvoltage protection range 0...92.4 V 0...92.4 V 0...92.4 V
Overcurrent protection range 0...3.3 A 0...5.5 A 0...11 A
Voltage regulation
Adjustment range 0...84 V 0...84 V 0...84 V
Accuracy
(1
(at 23 ± 5°C) < 0.2% U
Max
< 0.2% U
Max
< 0.2% U
Max
Load regulation at 0...100% load < 0.15% U
Max
< 0.15% U
Max
< 0.15% U
Max
Settling time after load step < 2 ms < 2 ms < 2 ms
Display: Accuracy
(3
≤0.2%U
Max
≤0.2%U
Max
≤0.2%U
Max
Ripple
(2
< 48 mV
PP
< 4 mV
RMS
< 96 mV
PP
< 24 mV
RMS
< 100 mV
PP
< 6 mV
RMS
Current regulation
Adjustment range 0...3 A 0...5 A 0...10 A
Accuracy
(1
(at 23 ± 5°C) < 0.3% I
Max
< 0.3% I
Max
< 0.3% I
Max
Loadregulationat0...100%ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 2 mA
RMS
< 3 mA
RMS
< 1.5 mA
RMS
Display: Accuracy
(3
≤0.2%I
Max
≤0.2%I
Max
≤0.2%I
Max
Miscellaneous
Cooling
Fanless, natural convec-
tion
Fanless, natural convec-
tion
Temperature controlled
fan
Noise - - < 40 dbA @ 1 m
Ambient temperature 0..50°C
Storage temperature -20...70°C
Humidity < 80%, not condensing
Standards EN 61010-1
Overvoltage category 2
Protection class 1
Terminals
Rear side AC input
Front side DC output, USB-B
Dimensions
Enclosure (WxHxD) 174 x 82 x 240 mm 174 x 82 x 240 mm 174 x 82 x 267 mm
Total (WxHxD) 174 x 90 x 263 mm 174 x 90 x 263 mm 174 x 90 x 290 mm
Weight ≈1.9kg ≈2kg ≈2.6kg
Article number 39200116 39200117 39200118
(1Relatedtothenominalvalues,theaccuracydenesthemaximumdeviationbetweenanadjustedvaluesandthetrue(actual)value.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz.
(3 The display error adds to the error of the related actual value on the DC output.