PS 3000 C Series
Submenu “Ethernet
Element Description
Port Default value: 5025
Adjust the socket port here, which belongs to the IP address and serves for TCP/P access
when controlling the device remotely via Ethernet
DNS address Default value: 0.0.0.0
Permanent manual setting of the network address of a domain name server (short: DNS)
which has to be present in order to translate the host name to the device’s IP, so the device
could alternatively access by the host name
Enable TCP
Keep-Alive
Default setting: disabled
Enables/disables the “keep-alive time” functionality of TCP.
Submenu “Communication Protocols
Element Description
Enabled Default setting: SCPI&ModBus
Enables/disables SCPI or ModBus RTU communication protocols for the device. The
changeisimmediatelyeectiveaftersubmittingitwithENTERbutton.Onlyoneofboth
can be disabled.
Submenu “Communication Timeout
Element Description
Timeout USB (ms) Default value: 5, Range: 5...65535
USB/RS232communicationtimeoutinmilliseconds.Denesthemax.timebetweentwo
subsequent bytes or blocks of a transferred message. For more information about the timeout
refer to the external programming documentation “Programming ModBus RTU & SCPI”.
Timeout ETH (s) Default value: 5, Range: 5...65535
Denesatimeoutafterwhichthedevicewouldclosethesocketconnectioniftherewas
no command communication between the controlling unit (PC, PLC etc.) and the device
fortheadjustedtime.Thetimeoutisineectiveaslongasoption“TCPKeep-alive”(see
above) is enabled.
3.4.3.7 Menu “HMI settings”
These settings refer exclusively to the control panel (HMI).
Element Description
Language Selection of the display language between German, English, Russian or Chinese.
Default setting: English
Backlight Setup The choice here is whether the backlight remains permanently on or if it should be switched
owhennoinputviapushbuttonsorrotaryknobisdonefor60s.Assoonasinputisdone,
the backlight returns automatically. Furthermore the backlight intensity can be adjusted here.
Default settings: 100, Always on
Status page Switchestoadierentmainscreenlayout.Theusercanselectbetweentwolayoutswhich
are depicted by small graphics as a preview. Also see section „3.4.6. Switching the main
screen view“.
Default setting: Layout 1
Key Sound Activates or deactivates sounds when pressing a button on the HMI. It can usefully signal
that the action has been accepted.
Defaultsetting:o
Alarm Sound Activatesordeactivatestheadditionalacousticsignalofanalarmoruserdenedeventwhich
has been set to “Action = ALARM”. See also „3.6 Alarms and monitoring“ on page 45.
Defaultsetting:o
HMI Lock See „3.7 Control panel (HMI) lock“ on page 46.
Default settings: Lock all, No