EL 3000 B Series
(1Fortechnicalspecicationsoftheanaloginterfacesee„3.5.4.4 Analog interface specication“ on page 39
400 W
Model
EL 3080-60 B EL 3200-25 B EL 3500-10 B
Analog interface (optional)
(1
Set value inputs U, I, P, R
Actual value output U, I
Control signals DC on/off, Remote control on/off, R mode on/off
Status signals CV, OVP, OT
Galvanic isolation to the device max. 1500 V DC
Sample rate (set value inputs) 500 Hz
Insulation
Input (DC) to enclosure
DC minus: permanent max. ±400 V
DCplus:permanentmax.±400V+max.inputvoltage
Input (AC) to input (DC) Max. 2500 V, short-term
Environment
Cooling Temperature controlled fans
Ambient temperature 0..50 °C
Storage temperature -20...70 °C
Digital interfaces
Optionally available
IF-KE5USB:1xUSB
IF-KE5USBLAN:1xUSB+1xLAN
IF-KE5USBANALOG:1xUSB+1xAnalog
Galvanic isolation to the device max. 1500 V DC
Terminals
Rear side AC input, analog interface (optional), USB (optional), Ethernet (optional)
Front side DC input, remote sensing
Dimensions
Enclosure (WxHxD) 260 x 88 x 325 mm
Total (WxHxD) 308 x max. 195 x mind. 361 mm
Standards EN 60950
Weight 4 kg 4 kg 4 kg
Article number 35320205 35320206 35320207