2.3.7.1 Cable lead and plastic cover
It is intended to connect the DC input cables (also for Sense) from the bottom side of the DC terminal:
Figure 10 - DC wiring example without remote sense (bridged) Figure 11 - DC wiring example with remote sense connected to source
For the connection of DC power cables we recommend to either use cable end-sleeves or spade lugs.
Required for the DC terminal:
• Cable end-sleeves (insulated): 0,5 mm² ... 4 mm², max. length of the end-sleeve 8 mm
• Spade lugs (insulated): 4mm
When wiring the DC input(s) and the network port(s) at the same time it is imperative to keep
distance between both lines! DC cables and network cables must not be tied together!
Figure 12 - Not allowed wiring Figure 13 - Allowed wiring (example)
The wiring example in Figure 13 is only one possible solution. It would even better to let the LAN cable lead away
to the top, so it does not obstruct the knob and the touch display remains fully accessible.
A plastic cover for contact protection on the DC terminal is included. It must always be installed.