User manual
Page 43
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
ELR/ELM 5000 Series
4.3 Firmware updates
Firmwareupdatesshouldonlybeinstallediftheycaneliminateexistingbugsinthermware
in the device or contain new features.
Thermwareoftheloadmodule,ifnecessary,isupdatedviathefrontsideUSBport.ItrequiresaFAT32format-
tedUSBstickwiththeupdatele.
► How to update the rmware:
1. Ifnotalreadyavailable,obtainaUSBashdrive(capacityupto32GB)andensurethatitisformattedas
FAT32.
2. Createa folder with the name HMI_FILES (case sensitive!) in the root directory of the ash drive and
copytheunpackedrmwareupdateletothisfolder.Thelenamemustbeginwithanumber.Example:
96230108_FW-ELR-MUL-HMI_V201.bin.
3. Tap the touch area , then , then “HMI Setup” and then “Firmware Update”.
4. In the screen, select touch area “HMI”.ConrmthesecurityquestionwithENTER,plugtheUSBstick.The
HMIwillthenreadandlistthedetectedupdatelesfoundintheHMI_FILESfolder.
5. Select and tick the update to be used and tap the touch area . The control panel will then be updated.
Oncenished,thedevicewillautomaticallyrestart.
6. Switch the equipment off, wait until it is completely off (fan not running anymore), then switch back on.
7. Check all settings in MENU and all set values.
It is recommended to perform a “Reset device” after every update. See section 3.4.3.1.
5. Accessories and options
5.1 Overview
Accessories and options are, when necessary, delivered with their own documentation and are not detailed further
in this document.
6. Service & Support
6.1 General
Repairs, if not otherwise arranged between supplier and customer, will be carried out by EA Elektro-Automatik.
Forthistheequipmentmustgenerallybereturnedtothemanufacturer.NoRMAnumberisneeded.Itissufcient
to package the equipment adequately and send it, together with a detailed description of the fault and, if still under
guarantee, a copy of the invoice, to the following address.
6.2 Contact options
Questionsorproblemswithoperationofthedevice,useofoptionalcomponents,withthedocumentationorsoft-
ware, can be addressed to technical support either by telephone or e-Mail.
Address e-Mail Telephone
EA Elektro-Automatik
Helmholtzstr. 31-33
41747 Viersen
Germany
All issues:
ea1974@elektroautomatik.de
Switchboard: +49 2162 / 37850
Support: +49 2162 / 378566