User manual
Page 18
ELR/ELM 5000 Series
www.elektroautomatik.de
ea1974@elektroautomatik.de
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
• Status area (grey)
This area displays various status texts:
Display Description
Locked The HMI is locked
Remote: LAN The device is under remote control via the built-in Ethernet interface
Local The device has been locked by the user explicitly against remote control
Alarm: Alarm condition which has not been acknowledged or still exists.
SEQ:
(only in remote mode) Sequence generator activated
1.9.5.2 Rotary knob
As long as the device is in manual operation the rotary knob is used to adjust set values as well as param-
eters in the setup menu (MENU) or the sequence generator. For a detailed description of the individual
functions see section „3.4 Manual operation“ on page 28.
1.9.5.3 Button function of the rotary knob
The rotary knob also has a pushbutton function, which is used in all menus and in the main screen to move the
cursor of the selected value clockwise (left to right), as shown below:
1.9.5.4 Resolution of the displayed values
In the display, set values can be adjusted in certain increments. The number of decimal places depends on the
device model. The values have 3 to 5 digits. Actual and set values always have the same number of digits.
Adjustment resolution and number of digits of set values in the display:
Voltage,
OVP, U-min, U-max
Current,
OCP, I-min, I-max
Power,
OPP, P-max
Nominal Digits
Min.
Increment
Nominal Digits
Min.
Increment
Nominal Digits
Min.
Increment
80 V 4 0.01 V 10 A / 25 A 5 0.001 A 320 W 3 1 W
200 V 5 0.01 V
1.9.5.5 USB-Port (Front side)
ThefrontalUSBport,locatedtotherightoftherotaryknob,isintendedfortheconnectionofstandardUSBash
drives(ashdrive).Itcanbeusedto:
• saveorloadsequencelesforthesequencegenerator
• updatetheHMIrmware
USB sticks must be FAT32 formatted and should have a maximum capacity of 32GB. Higher storage capacity
maybeacceptedalso.AllsupportedlesmustbeheldinadesignatedfolderintherootpathoftheUSBdrivein
order to be found. This folder must be named HMI_FILES, such that a PC would recognise the path G:\HMI_FILES
ifthedriveweretobeassignedtheletterG.Thecontrolpaneloftheelectronicloadcanreadthefollowingle
typesfromaashdrive:
*.bin Firmware updates only for the control panel. The folder name format is given,
like 96230108_FW-ELR-MUL-HMI_V201.bin, and probably listed in short form
asFW-ELR-MUL-HMI_V201.bin.OtherBINleswon’tberecognisedorlisted.
wave_<arbitrary_text>.csv Sequence for sequence generator for use on voltage (U), current (I) and power
(P)