Manual

Table Of Contents
© EA Elektro-Automatik in 2022, this information is subject to change without notice 1533200840_manual_elr_10000_2u_3kw_en_02
Technical speci cations ELR 10080-120 ELR 10200-50 ELR 10360-30 ELR 10500-20 ELR 10750-12
DC input
Voltage range 0 - 80 V 0 -200 V 0 - 360 V 0 - 500 V 0 - 750 V
U
Min
for I
Max
0.8 V 2 V 2 V 2.5 V 2.5 V
Current range 0 - 120 A 0 - 50 A 0 - 30 A 0 - 20 A 0 - 12 A
Power range
*1 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W)
Resistance range 0.02 Ω - 40 Ω 0.1 Ω - 250 Ω 0.4 Ω -800 Ω 1 Ω - 1500 Ω 2 Ω - 3000 Ω
Output capacity 17280 μF 1600 μF 660 μF 240 μF 80 μF
Effi ciency ≤94%
*2 ≤94.5% *2 ≤94.5% *2 ≤95% *2 ≤95% *2
Insulation
Negative DC pole <-> PE ±600 V DC ±1000 V DC ±1000 V DC ±1500 V DC ±1500 V DC
Positive DC pole <-> PE +600 V DC +1000 V DC +1000 V DC +2000 V DC +2000 V DC
Article number 33200845 33200846 33200847 33200848 33200849
Technical speci cations ELR 11000-10 ELR 11500-06
DC input
Voltage range 0 - 1000 V 0 - 1500 V
U
Min
for I
Max
4 V 4.2 V
Current range 0 - 10 A 0 - 6 A
Power range
*1 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W)
Resistance range 3 Ω - 6000 Ω 8 Ω -6000 Ω
Output capacity 60 μF 20 μF
Effi ciency ≤95%
*2 ≤95% *2
Insulation
Negative DC pole <-> PE ±1500 V DC ±1500 V DC
Positive DC pole <-> PE +2000 V DC +2000 V DC
Article number 33200850 33200851
*1 The value in brackets applies to the state of derating (power reduction) for 110 to 127 V ±10% utility
*2 At 100% power and 100% input voltage
*1 The value in brackets applies to the state of derating (power reduction) for 110 to 127 V ±10% utility
*2 At 100% power and 100% input voltage