User manual
Page 52
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
EL 9000 B HP Series
3.5.4.5 Overview of the Sub-D Socket
3.5.4.6 Simplied diagram of the pins
+
Digital Input (DI)
It requires to use a switch with low resist-
ance (relay, switch, circuit breaker etc.) in
order to send a clean signal to the DGND.
V~0.5
AGND
Analog Input (AI)
High resistance input (impedance
>40k....100kΩ)foranOAcircuit.
4.7k
12V
+10V
Digital Output (DO)
A quasi open collector, realised as high
resistance pull-up against the internal sup-
ply. In condition LOW it can carry no load,
merely switch, as shown in the diagram
with a relay as example.
V~2
AGND
Analog Output (AO)
Output from an OA circuit, only low
impedance.Seespecicationstable
above.
3.5.4.7 Application examples
a) Switching off the DC input via the pin “REM-SB”
A digital output, e.g. from a PLC, may be unable to cleanly effect this as it may
not be of low enough resistance. Check the specication of the controlling ap-
plication. Also see pin diagrams above.
In remote control, pin REM-SB is be used to switch the DC input of the device on and off. This is
also available without remote control being active.
It is recommended that a low resistance contact such as a switch, relay or transistor is used to
switch the pin to ground (DGND).
Following situations can occur:
• Remote control has been activated
During remote control via analog interface, only pin “REM-SB” determines the states of the DC input, according to
thelevelsdenitionsin3.5.4.4. The logical function and the default levels can be inverted by a parameter in the
setup menu of the device. See 3.4.3.1.
If the pin is unconnected or the connected contact is open, the pin will be HIGH. With parameter
“Analog interface REM-SB” being set to “normal”, it requests “DC input on”. So when activating
remote control, the DC input would instantly switch on.