3.4 Manual operation
3.4.1 Powering the device
The device should, as far as possible, always be switched on using the toggle switch on the front of the device.
Alternatively this can take place using an external cutout (contactor, circuit breaker) of suitable current capacity.
Afterswitchingon,thedisplayrstsshowthemanufacturerslogoanddevicerelatedinformation,aswellasa
language selection screen (for 3 s) and will then be ready for use. In setup (see section „3.4.3. Conguration via
MENU“), in the second level menu “General settings” is an option “Input after power ON” in which the user can
determine the condition of the DC input after power-up. Factory setting here is “OFF”, meaning that the DC input
will always be switched off on power-up, while “Restore” means that the last condition of the DC input will be
restored, either on or off. All set values are also restored.
3.4.2 Switching the device off
On switch-off, the last input condition and the most recent set values and input status, as well as activated master-
slave operation are saved. Furthermore, a PF alarm (power failure) will be reported, but has to be ignored here.
The DC input is immediately switched off and after a short while fans will shut down and after another few seconds
the device will be completely powered off.
3.4.3 Conguration via MENU
TheMENUservestocongurealloperatingparameterswhich
arenotconstantlyrequired.Thesecanbesetbyngertouchon
the MENU touch area, but only if the DC input is switched OFF.
Seeguretotheright.
If the DC input is switched on the settings menu will not be shown,
only status information.
Menunavigationisbyngertouch.Valuesaresetusingtherotary
knobs. The assignment of the knobs to the adjustable values is not
indicated in menu pages, but there is an assignment rule: upper
value -> lefthand knob, lower values -> righthand knob.
The menu structure is shown schematically on the following pages.
Some setting parameters are self-explanatory, others are not. The
latter will be explained on the pages following.