EL 9000 B HP Series
1.9.6 USB-Port Type B (Back side)
The USB-B port on the back side of the device is provided for communication with
thedeviceandforrmwareupdates.TheincludedUSBcablecanbeusedtoconnect
the device to a PC (USB 2.0 or 3.0). The driver is delivered on the included medium
(USB stick) and installs a virtual COM port.
The device can be addressed via this port either using the international standard
ModBus protocol or by SCPI language. The device recognises the message proto-
col used automatically. Details for remote control can be found on the web site of
Elektro-Automatik or on the included medium.
If remote control is in operation the USB port has no priority over either the interface
module (see below) or the analog interface and can, therefore, only be used alter-
natively to these. However, monitoring is always available.
1.9.7 Interface module slot
This slot on the back side of the device is used to install one of various modules of
the IF-AB interface series. The following options are available:
Ordering no. Name Description
35400100 IF-AB-CANO CANopen, 1x Sub-D 9pole male
35400101 IF-AB-RS232 RS 232, 1x Sub-D 9pole male (null modem)
35400103 IF-AB-PBUS ProbusDP-V1Slave,1xSub-D9polefemale
35400104 IF-AB-ETH1P Ethernet, 1x RJ45
35400105 IF-AB-PNET1P ProNETIO,1xRJ45
35400107 IF-AB-MBUS1P ModBus TCP, 1x RJ45
35400108 IF-AB-ETH2P Ethernet, 2x RJ45
35400109 IF-AB-MBUS2P ModBus TCP, 2x RJ45
35400110 IF-AB-PNET2P ProNETIO,2xRJ45
35400111 IF-AB-CAN CAN 2.0A & 2.0B, 1x Sub-D 9pole male
Themodulesareinstalledbytheuserandcanberetrottedwithoutproblem.Armwareupdateofthedevicemay
be necessary in order to recognize and support certain modules.
If remote control is in operation the interface module has no priority over either the USB port or the analog interface
and can, therefore, only be used alternately to these. However, monitoring is always available.
Switch off device before adding or removing modules!
1.9.8 Analog interface
This 15 pole Sub-D socket on the back side of the device is provided for remote
control of the device via analog or digital signals.
If remote control is in operation this analog interface can only be used alternately to
the digital interface. However, monitoring is always available.
The input voltage range of the set values and the output voltage range of the monitor
values, as well as reference voltage level can be switched in the settings menu of