ELR 9000 Series
10.5 kW
Model
ELR 9080-510 ELR 9250-210 ELR 9500-90 ELR 9750-66 ELR 91500-30
Analog interface
(3
Set value inputs U, I, P U, I, P U, I, P U, I, P U, I, P
Actual value output U, I U, I U, I U, I U, I
Control signals
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
Status signals CV, OVP, OT CV, OVP, OT CV, OVP, OT CV, OVP, OT CV, OVP, OT
Galvanic isolation to the device
max. 1500 V
DC
max. 1500 V
DC
max. 1500 V
DC
max. 1500 V
DC
max. 1500 V
DC
Insulation
Input (DC) to enclosure
DC minus: permanent max. 400 V
DC plus: permanent max. 400 V + max. input voltage
Input (AC) to input (DC) Max. 2500 V, short-term
Environment
Cooling Temperature controlled fans
Ambient temperature 0..50 °C
Storage temperature -20...70 °C
Digital interfaces
Featured
1x USB-B for communication, 1x USB-A for functions and HMI rmware updates, 1x
Master-slave bus, 1x GPIB (optional)
Slot for AnyBus modules
(2
CANopen, Probus, Pronet, RS232, Devicenet, Ethernet, ModBus
Galvanic isolation to the device max. 1500 V DC
Terminals
Rear side
Share Bus, DC input, AC input/output, remote sensing, analog interface, USB-B,
master-slave bus, AnyBus module slot
Front side USB-A
Dimensions
Enclosure (WxHxD) 19“ x 3U x 609 mm
Total (WxHxD) 483 mm x 133 mm x 714 mm
Standards EN 60950, EN 50160 (grid class 2),
Weight 31 kg 31 kg 31 kg 31 kg 31 kg
Article number