User manual
Page 11
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
ELR 9000 Series
3.5 kW
Model
ELR 9080-170 ELR 9250-70 ELR 9500-30 ELR 9750-22
Analog interface
(1
Set value inputs U, I, P U, I, P U, I, P U, I, P
Actual value output U, I U, I U, I U, I
Control signals
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
Status signals CV, OVP, OT CV, OVP, OT CV, OVP, OT CV, OVP, OT
Galvanic isolation to the device max. 1500 V DC max. 1500 V DC max. 1500 V DC max. 1500 V DC
Insulation
Input (DC) to enclosure
DC minus: permanent max. 400 V
DC plus: permanent max. 400 V + max. input voltage
Input (AC) to input (DC) Max. 2500 V, short-term
Environment
Cooling Temperature controlled fans
Ambient temperature 0..50 °C
Storage temperature -20...70 °C
Digital interfaces
Featured
1x USB-B for communication, 1x USB-A for functions and HMI rmware updates,
1x Master-slave bus, 1x GPIB (optional)
Slot for AnyBus modules
(2
CANopen, Probus, Pronet, RS232, Devicenet, Ethernet, ModBus
Galvanic isolation to the device max. 1500 V DC
Terminals
Rear side
Share Bus, DC input, AC input/output, remote sensing, analog interface, USB-B,
master-slave bus, AnyBus module slot
Front side USB-A
Dimensions
Enclosure (WxHxD) 19“ x 3U x 609 mm
Total (WxHxD) 483 mm x 133 mm x 714 mm
Standards EN 60950, EN 50160 (grid class 2)
Weight 17 kg 17 kg 17 kg 17 kg
Article number
(3
33200401 33200402 33200403 33200404
(1 For technical specications of the analog interface see „3.5.4.3 Analog interface specication“ on page 51
(2 Only in the standard version
(3 Article number of the standard version, devices with options will have a different number