User manual

Page 44
ELR 9000 Series
www.elektroautomatik.de
ea1974@elektroautomatik.de
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
IF Level 1 Description
Probus DP
Node Address Selection of the Probus or node address of the device within range 1...125 via
direct input
Function Tag String input box for a user-denable text which describes the Probus slave function
tag. Max. length: 32 characters
Location Tag String input box for a user-denable text which describes the Probus slave location
tag. Max. length: 22 characters
Installation Date String input box for a user-denable text which describes the Probus slave instal-
lation date tag. Max. length: 40 characters
Description String input box for a user-denable text which describes the Probus slave.
Max. length: 54 characters
IF Level 1 Description
RS232
- Die Baudrate ist einstellbar, weitere serielle Einstellungen sind wie folgt festgelegt:
8 Datenbits, 1 Stopbit, Parität = keine
Baudrateneinstellungen: 2400, 4800, 9600, 19200, 38400, 57600, 115200
IF Level 1 Level 2 Level 3 Description
Pronet/IO, 1 & 2 Port
IP Settings DHCP The IF allows a DHCP server to allocate an IP address, a subnet
mask and a gateway. If no DHCP server is in the network then net-
work parameters will be set as dened in point “Manual”
Manual IP This option is activated by default. An IP address can be maually
allocated.
Gateway Here a gateway address can be allocated if required..
Subnet Here a subnet mask can be dened if the default subnet mask is
not suitable.
DNS 1 Here the addresses of the rst and second Domain Name Servers
(DNS) can be dened, if needed. A DNS is only necessary if the
device has Internet access and should call Internet URLs, e.g. an
internal eMail system, in order to send an eMail.
DNS 2
Port Range: 0...65535. Default ports:
5025 = Modbus RTU (for Modbus & SCPI)
Host name Free choice of host name (default: Client)
Domain name Free choice of Domain (default: Workgroup)
SMTP
Settings
Server IP Mail server address, used to send eMails via this mail server, in
order to e.g. report an alarm.
Username Login to Mailserver, Username
Password Login to Mailserver, Password
Function Tag String input box for a user-denable text which describes the Pronet slave function tag.
Max. length: 32 characters
Location Tag String input box for a user-denable text which describes the Pronet slave location tag.
Max. length: 22 characters
Station Name String input box for a user-denable text which describes the Pronet station name.
Max. length: 54 characters
Description String input box for a user-denable text which describes the Probus slave.
Max. length: 54 characters
Installation Date String input box for a user-denable text which describes the Probus slave installation
date tag. Max. length: 40 characters
IF Level 1 Description
Devicenet
Node Address Selection of the Devicenet node address in the range 0...63 via direct input
Baud Rate Selection of the data communication speed with 125 kbps, 250 kbps or 500 kbps (1 kbps
= 1024 Baud) as bus baud rate. Selection „AUTO“ will let the slave device wait for the
master to initiate bus trafc in order to detect the baud rate on the bus automatically