User manual

28
EN
Instruction Manual
EL 9000 HP Series
Date: 10-31-2011
About the device
2.2 Devicespecicdata
Mainsinput
Mains voltage
Mains frequency
Mains fuse
DCinput
Input voltage U
nom
80V 160V 400V 750V
Input power P
nom
Permanent input power
Input current I
nom
200A 100A 50A 25A
Overvoltage protection threshold
max. allowed input voltage 100V 180V 500V 850V
Voltagecontrol
Adjustment range 0…80V 0…160V 0…400V 0…750V
Display resolution 100mV 100mV 100mV 100mV
Accuracy** <0,2% of Unom
Currentcontrol
Adjustment range 0…200A 0…100A 0…50A 0…25A
Display resolution 100mA 100mA 10mA 10mA
Accuracy**
Powercontrol
Adjustment range 0…2400W 0…2400W 0…2400W 0…2400W
Display resolution 1W 1W 1W 1W
Accuracy**
Resistancecontrol
Adjustment range 1 0…5 0…10 0…10 0…40
Display resolution 1m 10m 10m 10m
Adjustment range 2 0…100 0…200 0…400 0…800
Display resolution 100m 100m 100m 100m
Accuracy**
Dynamicvalues
Current rise and fall time***
Level
Times (pulsed operation)
Rise/fall time
Accuracy**
Trigger input*
Batterytestfeature
Modes
Battery protection
Display
Display
Analogueinterface*
Set value inputs
Monitor outputs
Control signals
Error signals
Outputs
Cooling
Type
Ambient temperature
Terminals
Load input
System Bus
Analogue interface
DimensionsWxHxD
Weight
Supportedinterfacecards
Articlenumber 33 200 240 33 200 242 33 200 244 33 200 249
* for technical specification see section "Analogue interface"
*** Rise and fall time are defined at 10%...90% and 90%...10% of the nominal value
All single values, which specify a tolerance are typical values
EL9160-100HP EL9400-50HP
0...10V for U / I (0...100% actual value)
0...10V for U / I / P / R (0...100% set value)
EL9080-200HP
T2,5A
2400W, with temperature depending derating
2400W at 40°C ambient temp.
EL9750-25HP
115V/230V selectable
50/60Hz
0…70°C with derating 20W/°C
2 x 40 characters, illuminated
time and consumed battery capacity
reference voltage
overvoltage / overtemperature
internal/external, input on/off, R range 1 or 2
final discharging voltage adjustable
** Accuracy is defined as the max. allowed difference between actual value and set value, always related to the nominal value.
Example: nom. value is 100A and accuracy is given with 0.2%. A set value of 20A may thus result in an actual value of 19.8A...20.2A.
temperature controlled fans
USB, RS232, CAN, GPIB, Ethernet
rear side, M8 screw terminal
rear side, 7 pole screw clamp
rear side, 15 pole Sub-D socket
19" x 3U x 460mm
17,5kg
current / resistance / power
yes, for external level switching
2 adjustable, 50us..100s
2 adjustable levels per control mode
<50us
<2% of the selected resistance range, 0,3% of the maximum input current
<0,1% of Unom
<2% of Pnom
1,1 * Unom
<0,2% of Inom
<10%
adjustable, 30us…200ms