User manual
28
EN
Instruction Manual
EL 9000 HP Series
Date: 10-31-2011
About the device
2.2 Devicespecicdata
Mainsinput
Mains voltage
Mains frequency
Mains fuse
DCinput
Input voltage U
nom
80V 160V 400V 750V
Input power P
nom
Permanent input power
Input current I
nom
200A 100A 50A 25A
Overvoltage protection threshold
max. allowed input voltage 100V 180V 500V 850V
Voltagecontrol
Adjustment range 0…80V 0…160V 0…400V 0…750V
Display resolution 100mV 100mV 100mV 100mV
Accuracy** <0,2% of Unom
Currentcontrol
Adjustment range 0…200A 0…100A 0…50A 0…25A
Display resolution 100mA 100mA 10mA 10mA
Accuracy**
Powercontrol
Adjustment range 0…2400W 0…2400W 0…2400W 0…2400W
Display resolution 1W 1W 1W 1W
Accuracy**
Resistancecontrol
Adjustment range 1 0…5Ω 0…10 0…10Ω 0…40Ω
Display resolution 1mΩ 10mΩ 10mΩ 10mΩ
Adjustment range 2 0…100Ω 0…200Ω 0…400Ω 0…800Ω
Display resolution 100mΩ 100mΩ 100mΩ 100mΩ
Accuracy**
Dynamicvalues
Current rise and fall time***
Level
Times (pulsed operation)
Rise/fall time
Accuracy**
Trigger input*
Batterytestfeature
Modes
Battery protection
Display
Display
Analogueinterface*
Set value inputs
Monitor outputs
Control signals
Error signals
Outputs
Cooling
Type
Ambient temperature
Terminals
Load input
System Bus
Analogue interface
DimensionsWxHxD
Weight
Supportedinterfacecards
Articlenumber 33 200 240 33 200 242 33 200 244 33 200 249
* for technical specification see section "Analogue interface"
*** Rise and fall time are defined at 10%...90% and 90%...10% of the nominal value
All single values, which specify a tolerance are typical values
EL9160-100HP EL9400-50HP
0...10V for U / I (0...100% actual value)
0...10V for U / I / P / R (0...100% set value)
EL9080-200HP
T2,5A
2400W, with temperature depending derating
2400W at 40°C ambient temp.
EL9750-25HP
115V/230V selectable
50/60Hz
0…70°C with derating 20W/°C
2 x 40 characters, illuminated
time and consumed battery capacity
reference voltage
overvoltage / overtemperature
internal/external, input on/off, R range 1 or 2
final discharging voltage adjustable
** Accuracy is defined as the max. allowed difference between actual value and set value, always related to the nominal value.
Example: nom. value is 100A and accuracy is given with 0.2%. A set value of 20A may thus result in an actual value of 19.8A...20.2A.
temperature controlled fans
USB, RS232, CAN, GPIB, Ethernet
rear side, M8 screw terminal
rear side, 7 pole screw clamp
rear side, 15 pole Sub-D socket
19" x 3U x 460mm
17,5kg
current / resistance / power
yes, for external level switching
2 adjustable, 50us..100s
2 adjustable levels per control mode
<50us
<2% of the selected resistance range, 0,3% of the maximum input current
<0,1% of Unom
<2% of Pnom
1,1 * Unom
<0,2% of Inom
<10%
adjustable, 30us…200ms