User manual
36
User Manual
Interface cards IF-XX
EN
Date: 04-09-2012
About the interface cards
if set to High Range and Default Level = L
U
in
= 0V 0mA
U
in
= 12V +1.6mA
U
in
= 24V +3.5mA
if set to High Range and Default Level = H
U
in
= 0V -1.5mA
U
in
= 12V +0.7mA
U
in
= 24V +4.5mA
Response time
1)
< 10ms
IF- G1 (GPIB)
Electrical isolation 2000V DC
Terminals 24pole Centronics socket (female)
Bus standard IEEE 488.1/2
Cable length (GPIB) 2m per device, 20m total
Cable type (GPIB) Standard GPIB cable
IF-E1 / IF-E1B (Ethernet)
Electrical isolation 1500V DC
Terminals 1x RJ45 (LAN / WAN)
1x USB, type A
Cable type (Ethernet) Twisted pair, patch cable,
Cat 3 or higher
Protocols HTTP, TCP/IP
Network ports IF-E1B 0 - 65535 (80=HTTP)
Default: 1001 (TCP/IP)
Netzwork ports IF-E1 80 (HTTP, TCP/IP)
Network connection 10/100 MBit
USB connection USB 1.1, 2.0
Transmission speed Ethernet 100 kBaud
Transmission speed USB 57600 Baud
Command interval max. every 300ms (IF-E2)
every 20ms (IF-E1B)
Keep-alive timeout (IF-E1B) 10min. (since v2.05)
IF-PB1 (Probus)
Electrical isolation 1000V DC
Terminals 1x Sub-D 9pole
1x USB, type A
Variant DP
Bus termination via Probus cable
Bus speed up to 12MBit/s
Protocols DPV0, DPV1
Identication with GSE le
1 Time between occurance of an event, that has to be signalised to an
output, and the moment it is signalised.
3. Installation
3.1 After unpacking
After unpacking, check the pluggable interface card(s) for
signs of physical damage. If any damage can be found do
not use and insert the card into any device!
3.2 Inserting a card
The card(s) must only be inserted while the unit is completely
switched off. The unit does not have to be opened. Remove
the screws from the slot cover or from an already equipped
card and remove the cover/card. Insert the new card with
caution until the card plate touches the rear side of the unit.
If there is space between the rear side and the card pla-
te, do not tighten the screws, because the card is not
placed correctly! The wiring between the PC and/or other
units has also be done before the unit is switched on again.
The card(s) will be automatically detected by the device after
powering it on and can now be configured.
Note about the IF-A1: before equipping the card, you should
set the jumpers correctly. Refer to „7.3 Configuring the IF-
A1“, subsection „Digital inputs“.
Note: in case the card was purchased subsequently and is
not recognized by the device, it might be necessary to update
the firmware of the device. Please contact your dealer for
further information.
Caution! There are components on the card which are sen-
sitive for ESD. You must follow the general ESD provi-sions
when handling and installing a card.
3.3 Combining interface cards
Only applies for series PSI 9000!
In case more than one card slot is used, the table shows
which cards can be combined (• means allowed):
IF-U1 IF-C1 IF-R1
IF-E1 /
IF-E1B
IF-G1 IF-A1 IF-PB1
IF-U1
- • - - • - -
IF-C1
• - • - - • •
IF-R1
- • - - • - -
IF-E1 /
IF-E1B
- - - - - - -
IF-G1
• - • - - • •
IF-A1
- • - - • - -
IF-PB1
- • - - • - -