User manual
40
© 2007, Elektro-Automatik GmbH & Co. KG
EN
About the interface cards
5. Usage in devices of the series
EL3000/EL9000
The electronic loads of the series EL3000 and EL9000 sup-
port the following interface cards:
IF-U1, IF-R1, IF-C1
The general functionality of the interface cards is the same
if used in one of these electronic loads. The amount of fea-
tures is limited, compared to a power supply, and there’s a
difference in configuring the cards in the setup menu.
Menu example of the CAN card:
Menu example RS232 card:
You can configure the interface cards in the setup menu of
the devices. This is activated by turning the switch Level
Control to position Setup.
Depending on which card is equipped (the electronic loads
feature only one card slot) a different selection of parameters
is available. The parameters and their values are identical to
the ones explained in section 4.1 to 4.3, with the exception
that no Sample point can be set at CAN.
There are also no settable parameters for the USB card
here.
Card found: IF-C1
CAN Baudrate: 10kBd
Card found: IF-C1
CAN Relocatable ID: 13
Card found: IF-C1
CAN Bus terminate: yes
Card found: IF-R1
RS232 Baudrate: 9600Bd