Datasheet

The interface cards are currently supported in the new series of power supplies PSI9000 and the new series of
eletronic loads EL3000/EL9000. This is an overview of the most important functions which are realisable by the
combination device<->card:
EA-Elektro-Automatik GmbH & Co. KG
Entwicklung - Produktion - Vertrieb
Helmholtzstraße 31-33
41747 Viersen
Telefon: 02162 / 37 85-0
Telefax: 02162 / 16 230
info@elektroautomatik.de
www.elektroautomatik.de
PSI 9000
EL3000/
EL9000
Set voltage/current
l l
Measure voltage/current
l l
Set power/internal resistance
3
l l
Measure power
l l
Load/save proles
4
l
-
Standby on/off
l l
Activate/deactivate Remote
l l
Gateway function
1,4
l
-
System Link Mode
2,4
l
-
Control function manager
4
l
-
Alarm management
l l
Supervision under-/overcurrent
4
l
-
Supervision under-/overvoltage
4
l
-
Set adjustment limits
4
l
-
Change operation mode
l l
Dene voltage range of in/out pins
l
-
Assign alarms to outputs
l
-
Reference/auxiliary voltage
l
-
Indicate regulation mode
l
-
1) at a combination of CAN&USB or CAN&RS232
2) only at USB card or RS232card
3) Internal resistance is only optional at series PSI9000
4) not at GPIB
all cards
dig. cards only analogue card only
About the gateway function:
For example, with a CAN card and a USB card equipped on one
unit you can link multiple devices with CAN (requires one CAN
card per unit) which are all controlled via USB. With the proper
software you are enabled to monitor and control multiple units
from one PC and with one USB port.
About the System Link Mode:
If multiple units are operated in serial or parallel connection they all
only show their own actual/set values. The System Link mode (only
available at IF-R1 and IF-U1) provides the additional features of
totals formation of voltage, current and power as well as an alarm
management for the linked units. The devices thus „behave“ like
one unit.