Using the power supply
7.6.4 Step response supervision
Step response +
The menu page Step responseletsyoucongurethesu-
pervision circuits for the dynamic and static comparison of actual
value and set value.
Supervise step: Default: U→Uo
Us→Uo Supervision of the deviance between set
value and actual value of voltage
Is→Io Supervision of the deviance between set
value and actual value of current
dyn. ∆U Default: 10% (of U
Nom
)
= 8.00V Allowed tolerance for the voltage
dyn. ∆I Default: 10% (of I
Nom
)
= 5.00A Allowed tolerance for the current
The settling process of the power supply is determined by the
load. After a set value has changed, a certain time elapses until
the desired value is put to the power output. For instance, it can
last some seconds for the voltage to go down from 100% to 0V at
no-load operation, because the output capacitors need a certain
time to discharge.
Supervision of a step response
The adjusted set value is compared with the measured actual
value. If there is a difference between them and this difference
is greater than the tolerance, the supervision will initiate an error
after the settling time Tsr.Seegurebelow.
Step response time
rise time Tsr =
{0…99:99h} Default: 100ms
fall time Tsf =
{0…99:99h} Default: 2s
Noticationsoftheset/actualcomparison
Example: The step from a lower set value to a higher set value
was not performed within the settling time Tsr. The supervision
erroristhennotiedasalarm,warningorsignal.
U or U or U
Dependingonthecongurationof
Supervise Step the
errors I or P arenotied.
Example: The step from a higher set value to a lower set value
was not performed within the settling time Tsf. The supervision
erroristhennotiedasalarm,warningorsignal.
U or U or U
Dependingonthecongurationof
Supervise Step the
errors I or P arenotied.
Part 2: The menu Options
Options +
The menu entryOptions leads you to following menu selec-
tion:
Resetconguration
Enable R mode
Setup lock
7.7 Resettodefaultconguration
Youcanresetallmodicationsofthesetuptothedefaultsetup
(the state the unit had when it was delivered).
After selecting the corresponding menu entry you will be promp-
ted again to submit the choice to reset your current, personal
conguration.
Attention:Evenifthedevicecongurationhasbeenlockedby
a PIN it will be unlocked and overwritten!
Resetconguration+
Are you sure ? Default: NO
= YES
Allmodicationsofthedefaultsetuparereset
= NO No change