6.11 Activating the menu
The main menu is acessed with the MENU button and
the display changes to the main menu level. A text menu like
this appears:
Prole
Settingupandselectinguserproles
Function Setting up a function sequence
Analogue interface
Settings for the internal analogue
interface
Communication Congurethedig.interfacecard
Options Default setup, unlock features,
Lockdeviceconguration
About…
Manufacturer, Service, SW version etc.
A menu page is left to the next higher level by pressing
the ESC button.
The SELECT keys are used to select another
menu entry.
The RETURN button then enters the menu entry into
the next sublevel by pressing it. The lowest menu level always
shows up as a parameter page. See next topic for details.
Using the power supply
Indication
Alarm
Warning
Warning
with auto
Simple
notification
Description
OV
Overvoltage at the power output
SYS
General system error
FCT
Function could not be saved and/or submitted
1)
2)
CAN
CAN bus transmission error
U>
def. def. def.
Overvoltage supervision threshold exceeded
U<
def. def. def.
Undervoltage supervision threshold exceeded
I>
def. def. def.
Overcurrent supervision threshold exceeded
I<
def. def. def.
Undercurrent supervision threshold exceeded
U
def. def. def.
Set-actual comparison error at a positive voltage transition
U
def. def. def.
Set-actual comparison error at a negative voltage transition
I
def. def. def.
Set-actual comparison error at a positive current transition
I
def. def. def.
Set-actual comparison error at a negative current transition
P
def. def. def.
Set-actual comparison error at a positive power transition
P
def. def. def.
Set-actual comparison error at a negative power transition
1)
OT disappear = OFF
2)
OT disappear = auto ON
def. = definable
Error type
Depending on
OT
Overtemperature error
6.12 Parameter pages
The parameter page is the lowest menu level. Here you can
change many different parameters in order to set up the de-
vice.
By pressing the ESC button the parameter page is left
to the next higher level and no parameters are accepted.
The SELECT keys are used to select a
different parameter. The selected parameter is then displayed
invertedly and can be changed with the left rotary knob.
The RETURN button submits the changed parameters,
which are accepted and stored and used. The parameter page is
also exited to the next higher level.
6.13 Alarms, warnings and signals
Alarms,warningsandsimplenotications(herecalled„signals“)
can be acoustically signallised or optically in the display (see
section„7.4Conguringthecontrolpanel“).
An alarm has a higher priority than a warning or signal. Up to four
alarms, warnings or signals can be displayed, which will cycle
in an interval of two seconds. If an alarm occurs, one previous
warning or signal will be suppressed if the total number exceeds
four.
The power supply monitors the interface cards for transmission
errorsaswelluser-denedwarningsandalarms.
The output voltage, the output current and the difference between
actual and set value can be monitored.
The table below gives an overview of the possible errors and
their meanings, as well as the selectable error types, as far as
thesearecongurable.