User manual
37
© 2009, Elektro-Automatik GmbH & Co. KG
EN
About the power supply
6. Handling
6.1 The display
Figure 3 shows an overview of the graphical display. During
normal operation, the display shows the actual and set values of
voltage (upper left), current (upper right) and power (lower left).
In device setup mode, it display parameters and settings.
The power set value is only displayed at models from 1kW which
feature power regulation.
In case the optional „internal resistance control“ is unlocked, the
power set value might be replaced by the internal resistance set
value, depending on what is selected in the device setup.
6.2 Used symbols
In the following description the display and operating elements
are marked differently by symbols.
= Displayed only, all elements which are only displayed
and which represent a state are marked with this symbol
= Parameter, changeable values, are marked with this
symbol and are emphasised
= Menu items, selectable, lead to the next sublevel or to
the bottom level with parameters
Brackets {…} mark possible options or adjustment ranges for
parameters.
6.3 Short overview about the display elements
Actual value of the output voltage
Actual value of the output current
Actual value of the output power
During normal operation the actual values are displayed in big
letters.
Set value of voltage
Target value of the desired output voltage (left knob). The value is
adjustedincoarse(decimalplacesleftofcomma)orne(decimal
placesrightofcomma).Switchingbetweencoarseandneis
done with the pushbuttons on the left rotary encoder.
Set value of current
Target value of the desired output current (right knob). The va-
lueisadjustedincoarse(decimalplacesleftofcomma)orne
(decimal places right of comma). Switching between coarse and
neisdonewiththepushbuttonsontherightrotaryencoder.It
might be required to push button before the set value is
adjustable.
Figure 3