User manual

39
© 2009, Elektro-Automatik GmbH & Co. KG
EN
Using the power supply
An alarm will shut down the output and has to be acknowledged
before the output can be switched on again (also see section
„6.14 Acknowledging alarms and warnings“).
A warning remains in display as long as it is not acknowledged
and can temporarily switch off the power output, if auto ONhas
been activated for a particular error.
A signal is only displayed and only as long as the cause of the
errorispersistent.Ifmorethanonesignalisnotied,theywill
cycle in the display in a 2s interval.
6.14 Acknowledging alarms and warnings
You can acknowledge alarms and warnings with the
ACK button.
If you acknowledge a warning with this button while it still per-
sists, it is turned into a signal and displayed furthermore. Else it
is deleted and not displayed anymore .
6.15 The function manager
The function manager is used to create functions which can con-
trol the unit automatedly. The user can build curves of set values
after the function f(U, I, t) with it. The function manager sets the
set values in an interval of 2ms. This means, that only times for
t of a multiple of 2ms can be set, for instance 50ms. If voltage
or current changes between two points, a ramp which consists
of a certain number of steps (t : 2ms, results in 25 steps for the
example above) is built.
The function manager controls the power supply and puts the
set values, which have been congured in the function. The
actual progression of the output values is however determined
by the load.
Explanation of the used terms:
Function = the function consists of up to 5 linked sequence
headers (starts in menu atSetup function), which can consist
ofupttovedifferentlycongurablesequences.
Function layout = the configurations in the function lay-
out are used by the function manager to set the operation
(U/I/P or U/I/R) mode for the power supply. Furthermore, the
repetition rate of the function and the arbitrary order of the se-
quences are set here. In dependency of the function layout the
function manager processes the next sequence after the previous
one has been processed and uses the settings from the sequence
control of the next sequence.
Sequence
= consists of the sequence control and 10 sequence
points. If the function manager is going to process a sequence,
itrstofallsetstheparametersgiveninthesequencecontrol.
The 10 sequence points are set conse-cutively and the whole
process is repeated as often as the repetition rate for the particular
sequence is set to.
Sequence control (Sequence control)=denestherepetition
rate of the sequence and the maximum set value of power during
the processing of the sequence, as well as internal resistance
(optionally, has to be unlocked)
Sequence point = a sequence always consists of 10 sequence
points. The points are processed (=set) conse-cutively by the
functionmanagerfrompoint0topoint9.Thedenitionofthe
sequence point determines, which set values for voltage and
current have to be reached after the given time t. This enables
the user to create step functions by setting the time to 0ms or
2ms, as well as ramps with times from 4ms to 99h99m. A time
value of 0ms is settable, but results in a real time value of 2ms,
because set values are only set in 2ms steps.
Additionally to the function itself you can set up and use the
supervision circuits in the proles.The function manager can
also be controlled via the communication with the interface cards
with one additional feature: you can set a stop point at which the
function shall stop.
Overview of the function manager display: