User's Manual

©e2v technologies (uk) limited 2010 107553 09 Aug 2010 DAS762156AA (UK) Version 11, page 44
The transmitter control module can be reset to a known configuration by applying a magnet to the
module adjacent to the antenna as shown.
Hold the magnet in position for 30 seconds while the transmitter is turned on.
The reset state is:
Connection Ad-Hoc
Channel 1
IP address 10.133.220.1
DHCP No – fixed addresses
SSID argus4
Encryption Off
This should be changed to the desired setting as soon as possible to avoid the possibility of two
reset transmitters coming within range and disrupting the network due to matching IP addresses.
The resetting and adjustment of these settings in the module is different across the various
versions of module firmware, please consult the factory for assistance.