Instruction Manual

12
9. TROUBLESHOOTING
●
Zero ow rate
●
Poor ow rate
●
Poor pressure
●
The pump starts and stops too frequently
●
Excessive current absorbed by the electro-pump
Possible causes related to the pump
(Motor and panel excluded)
Solution
██ █ Well water level too low Wait until well water level is restored, or if
possible, lower the pump further
██ Suction screen clogged Pull out the assembly and clean it
██ Delivery valve closed or blocked Find and replace the defective valve
█ █ Pump silted up Pull out the assembly and clean it
██ █ Wrong direction of rotation Carry out instructions as in 4.2
█ █ Pump capacity exceeds well capacity Replace pump with one of lower capacity
█ Leaks in the system Locate leaks and repair them
█ Worn pump Pull out the assembly and overhaul it
█ Pressure switch or level control improperly set Adjust setting
█ Tank too small Replace tank with a larger one
█ Mechanical friction Pull out the pump and overhaul it