Instruction Manual

12
9. TROUBLESHOOTING
Zero ow rate
Poor ow rate
Poor pressure
The pump starts and stops too frequently
Excessive current absorbed by the electro-pump
Possible causes related to the pump
(Motor and panel excluded)
Solution
Well water level too low Wait until well water level is restored, or if
possible, lower the pump further
Suction screen clogged Pull out the assembly and clean it
Delivery valve closed or blocked Find and replace the defective valve
Pump silted up Pull out the assembly and clean it
Wrong direction of rotation Carry out instructions as in 4.2
Pump capacity exceeds well capacity Replace pump with one of lower capacity
Leaks in the system Locate leaks and repair them
Worn pump Pull out the assembly and overhaul it
Pressure switch or level control improperly set Adjust setting
Tank too small Replace tank with a larger one
Mechanical friction Pull out the pump and overhaul it