Operating instructions
4
UNIT FEATURES
Fig. 2 – E-TAC Front Panel
are different than those found on standard PTAC
models. The owner must be familiar with these
features in order to fully understand the operation and
capability of the unit.
computer that utilizes real time diagnostics to prolong
the life of your unit. There is an LED indicator on the
control board, behind the front panel, that will flash
an error code if the unit has detected some kind of
fault condition. In many cases, the unit will
automatically clear th
e fault condition and continue
operating with no interruption. In some cases, the
condition cannot be cleared and the unit will require
service. In those cases, an “Fx” failure mode will be
displayed on the digital display. For a detailed list of
all error codes and “Fx” conditions, see Table 6 --
S tatus LED Indicator D efinitions for further details.
power is lost, all of the control settings (setpoint,
mode, fan speed, on/off and configuration) are
remembered. So when power is
restored, the unit will
start back up in the mode (and configuration) it was
in, when power was lost.
• Random Compressor restart -- To help prevent
power surges after a power outage (from many of
your E-TACs starting at the same time), the
compressor is equipped with a 2:45 to 3:15 random
restart delay feature. Whenever the unit is plugged in,
or power has been restarted, a rand
om compressor
restart will occur.
• Compressor Protection -- To prevent short cycling
of the compressor and maximize
it’s life, there is a
random start--up delay of 3 minutes on the
compressor and a minimum compressor run time of 3
minutes.
• Automatic room freeze protection – automatically
will keep the temperature in the room from getting
too cold, where water pipes might freeze. If the unit
is configured for the freeze protection feature to be
active (which is the default condition), then whenever
power is supplied to the unit, if the unit senses
temperature below 40°F (4.4°C), the fan motor and
electri
c heater are turned on and will warm the room
to 50° F (10°C). If Freeze protection is not required,
change the configuration switch to turn the feature off
(see section on unit configuration).
• Automatic defrost protection (for heat pump
models only) – When the outdoor temperature gets
too cold (approx. 40°F / 4.4°C) and the unit can no
longer effectively heat wit
h the compressor, the unit
will automatically switch to electric heating. The unit
will then heat with electric h
eat until the outside
temperature rises enough (approx. 40°F / 4.4°C), so
the compressor can be used again.
• Automatic Quick Warm--up (for heat pump
models only) -- If the room temperature falls to 5°F
(2.8°C) below the set point temperature, the reverse
cycle heat is shut off and the electric strip heat is
turned on for one cycle, until heating is satisfied.
• LED Indicator’s and Buttons -- The touch pad has
buttons for MODE, FAN SPEED, ON/OFF,
SETPOINT UP and SETPOIN
T DOWN. I
t also has
LEDs that correspond to the mode, fan speed and
setpoint operation, to indicate the unit’s status. The
LEDs below the mode button, FAN, COOL, and
HEAT, indicate what operating mode is active. The
LEDs below the Fan button, Low, Med and Hi,
indicate the fan speed that is selected. The LED
located in the lower right corner is the unit On/Off
status LED. If the unit is in ON mode, the LED will
be green. If the unit is OFF, the LED will be red.
• Configure Fan to Optimize Selected Application
 –
Unit  can  be  optimized  to  selected  application  by 
configuring
 the fan to run in continuous mode or cycle 
on and off with the compressor and electric heater (can 
be  different  for  both  heating  and  cooling  modes).  In 
cycle mode, fan will continue to run 60 seconds after 
compressor or electric heater  stops in order blow  off 
any residual heat or cool left on coil.
•  Dry  Mode  –  will  help  to  manage  and  reduce  the 
humidity in the room, making it more comfortable. In 
DRY  mode,  the  unit  will  modulate  cooling  mode  at 
low fan speed until the room temperature is 4 deg. F 
below the room temperature setting regardless of fan 
mode selection. Dry mode should not be considered a 
substitute for a stand alone dehumidifier.
•  Memory  –  Your  E-TAC  unit  also  has  memory.  If
This  E-TAC  has  many  exciting  features  which
• Premium Sound – Your Premium E-TAC is also the 
quietest  PTAC ever.  Not  only does  it  have 2  fan 
motors  and  a  tangential  blower  wheel  for  optimum 
sound, the indoor fan will always run a minimum of 10 
seconds  before  the compressor,  to help  reduce any 
compressor starting noise.
• Intelligence – Your E-TAC unit has an on board