Specifications

PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R130172 Platform Tuning
Table 5-1 Motor Drive Parmeters
Note: Motor Drive assemblies shipped from Columbus, Ohio arrive
preprogrammed with the standard Scanning Platform setup. For
Smart U-Frames, the values for Codes 202 and 306 may need to be
adjusted manually for different frame conditions.
Code Name
Controller Vendor
Default Values
Scanning Platform
Default Values
Smart U-Frame
Values
Group 01: ACTUAL VALUES AND STATUS
101 f
ref
(Info Only) (Info Only) (Info Only)
102 Last Fault (Info Only) (Info Only) (Info Only)
103 Version (Info Only) (Info Only) (Info Only)
Group 02: MOTOR VALUES AND LIMITS
201 U
nom
230 V 230 V 230 V
202 f
nom
50 Hz 130 Hz 95 Hz
203 I
nom
2.2 Amp 1.1 Amp 1.1 Amp
204 Nom Speed 1440 rpm 1800 rpm 1800 rpm
205 I
max
3.3 Amp 2.5 Amp 2.5 Amp
206 f
max
50 Hz 120 Hz 120 Hz
207 f
min
0 Hz 0 Hz 0 Hz
208Dir Lock111
209 Motor Noise 0 0 0
Group 03: DRIVE CONTROL
301Stop111
302Ramp000
303 Acc 5.0 sec 1.0 sec 1.0 sec
304 Dec 5.0 sec 0.5 sec 0.5 sec
305 U/f Ratio 1 1 1
306 IR Comp 10 VAC 15 VAC 15 VAC
307 DC Inj Time 0.0 sec 0.0 sec 0.0 sec
308 UC
max
Control111
Group 04: INPUT/OUTPUT
401Al min0%0%0%
402 Al max 100% 100% 100%
403 Ref min 0 Hz 0 Hz 0 Hz
404 Ref max 50 Hz 120 Hz 120 Hz
405 DI Config 1 1 1
406 Const speed 5 Hz 5 Hz 5 Hz
Group 05: SUPERVISION
501Al Fault011
502 f
lim
35 Hz 0 0
503 Param Lock 1 1 1