3BUS 208 000 R1301 57Utility Service Installation
Air and Water Supply
Sensors require clean, oil free, dry compressed air for operation. The pressure at
the platform air inlet ports must be at least 4.4 bar (65 psi) and a maximum of
5.4 bar (80 psi). The air flow depends upon the sensor configuration and the
adjustment of the manifold valves (the range is typically 0.37
m
3
/min (13 scfm) to
0.6 m
3
/min (21 scfm). Refer to the appropriate sensor manuals for further
information.
The liquid cooling unit provides a closed loop water circulation system to the
electronics on the platform and IR sensors. The liquid cooling unit requires
secondary heat exchange, a water supply of less than 80
°F (27 °C), and a flow of
typically less than 5 liters/min (1.5 gpm). Figure 4-2 on page 58 illustrates a typical
hook-up.
During installation make sure that the liquid cooling unit is filled according to
instructions and that the air supply is on before proceeding with the electrical power
up.