Specifications
PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R1301 255Service Workstation Activities
Preparing On–Site Documentation
Each time the Scanning Platform subsystem is restarted, it dynamically recreates
the various objects and their linkages. As a result, the absolute address of any object
and their associated instance variables can change from startup to startup.
Therefore, access to the various instance variables and objects is primarily done
through ASCII names and tokens. These are used as arguments to the utility
commands which in turn gives access to the data in memory.
It is important to have available the lists of names and token numbers which are
recognizable within the subsystem. This section identifies the activities which must
be done to obtain these name and token lists. In some cases, the list should be
printed out each time the system is upgraded. This will insure that certain address
locations can be accessed for troubleshooting purposes in case of processor halts.
See Table A-2.
Table A-2 Hardcopy Reports for On–Site Documentation
(Continued on next page)
Report
Name
Utility Command Printout
Frequency
Purpose
Sub-System
Release
Levels
.D/ss01/clm/revid First startup Gives a list of the release
levels within the system
Module Map map -m Each upgrade Provides the name, type,
and stack size of each
module in the order in
which it was loaded
inspect
Utility Object
Names
inspect
:global
First startup Provides a list of module
names which will be
recognized by the
inspect utility
Scanner and
Sensor
Instance
Variable List
inspect
<each object>
(see partial list below)
scanner01
betaSensor01
IRSensor01
caliperSensor01
ashSensor01
optipakSensor01
pmmFrame01
After
calibration,
tuning, and
setup for each
scanner and
sensor has been
completed or
changed
Provides a complete list
of the instance variables,
their names and current
values, as a record of
setup and calibration
activity