Specifications

PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R1301 253Service Workstation Activities
Identifying Sensor Configuration
To examine the current configuration of a scanner, follow the steps below.
1. At the $$ prompt type inspect.
2. At the I> prompt type:
( ) [scanner01 print] for the frame community
or ( ) [pmmInterface01 print] for the pmm community.
3. You will receive a printout. See the examples below.
The Scanner01 printout contains the following information.
Example: scanner01 (Scanner1180M) : with AEOS
sheetBrkDet01 (SheetBrkDet)
Servo01 (Servo)
head01 (Head)
Real Sensors:
BetaSensor01 (BetaSensor):with ATC
IRSensor01 (IRSensor) : Type HEMI+
Derived Sensors:
CondWtSensor01 (CondWtSensor)
Sensors Not In Operation:
(any sensors which are asleep)
The pmmInterface0x printout contains the following information.
Example: pmmInterface (PmmInterface)
pmmDriver (PmmDriver):
pmmFrames:
pmmFrame01 (Pmm Frame)
pmmSensors:
pmmBeta01 (Pmm Beta)
pmmCondWt01 (pmmCondWt)
pmmIRSensor01 (pmmIRSensor)