3BUS 208 000 R1301 249Service Workstation Activities
Calibrate Sample Report
The procedure for displaying the Calibrate Sample report is as follows:
1. Access the inspect utility.
2. Type: betaSensor01->calibrateSampleResults (example for basis weight)
The system will report back the address of that report.
3. Type in the address of the report.
The system will display the results of the last Calibrate Sample. See Figure A-4.
|---------------------------------------------------------------------|
|I> betaSensor01->calibrateSampleResults |
| calibrateSampleResults: 0x312c7a |
|I> 0x312c7a |
| 0x312c7a (id) |
| |
| 0x312c7a: “0x312c7a” (struct_PRIVATE) |
| isa: BWCalSmRslt (struct_SHARED *) |
| mySelf: 0x312c7a (long) |
| problemList: 0x308b22 (id) |
| name: 0x26b182 (id) |
| headPosition: 64 (double) |
| transPPT: 602.285 (double) |
| mylarWt: 29.3038 (double) |
| slope: 1 (double) |
| offset: 0 (double) |
| tempCompFlag: 0 ’\0’ (char) |
| tempComp: 0.802075 (double) |
| wtTempComp: 0 (double) |
| processBW: 29.3038 (double) |
|---------------------------------------------------------------------|
Figure A-4 Example of Calibrate Sample Report