3BUS 208 000 R1301188 Maintenance Procedures
Inspecting the Compressed Air Filters
The Scanning Platform requires good quality compressed air. Air pressure to the
platform must never be below 4.5 bar (65 psi). Contaminants are filtered through
the incoming air filters. The frequency with which the compressed air filters are
changed depends upon the amount of contaminants in the mill air supply and the
type of filter used. Inspect the filter once a week for the first three weeks to gauge
the frequency that the filter needs to be cleaned.
Cleaning the Compressed Air Filter
1. Press the OFF SHEET push button on the control panel.
2. Turn off the main AC circuit breaker at the Scanning Platform idler side power
entrance module.
3. Turn off the main air valve.
4. Replace or clean the filter.
5. Turn on the main air valve.
6. Turn on power to the platform. Wait five minutes for stabilization, then perform
a standardize.