Specifications
PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R1301156 Measurement Setup
Default Compensations for IR Moisture,
Microwave, & Ash Sensors
IR Moisture, Microwave, and Ash sensors are dependent sensors requiring
compensation from other process parameters. The requirements for each sensor are
as follows:
Table 6-29 Default Compensation Requirements
Each of these sensors must have their compensating input values established within
the Host Computer Grade File for each customer grade, even if the sensor has been
configured to use the internal (measured) value for its compensation. This is so
that, if the internal (measured) value becomes unavailable for one reason or another,
there will be a reasonable compensation signal available for the dependent sensor
coming from the Grade File. Refer to the Host computer documentation for details
on setting up the respective Grade Files.
Dependent Sensor Compensation Required
IR Moisture Sensor
Basis Weight (in 2-Filter mode)
Ash (in HemiPlus mode)
Microwave Sensor
Basis Weight
Sheet Temperature (optional)
Ash Sensor
Basis Weight
Moisture