3BUS 208 000 R1301 155Measurement Setup
Digital Input Invert Adjustment for the
Smoothness Sensor
The first Smoothness sensor on the Scanning Platform (smoothness Sensor A01)
must have the two digital inputs for temperature alarm and validity, inverted before
being processed by the MPRC software. To do this, proceed as follows:
1. Activate the dim utility.
2. Select the digital inputs for the ucGeneral board.
3. Invert bit 0 by pressing i, then 0, then <return> twice.
Observe that the Invert bit gets set and that the value changes to a 1.
4. Repeat step 3 for bit 1.
5. Press q and respond affirmatively when asked if the mask changes are to be used.
6. Press q repeatedly until $$ prompt returns. Do a gstore to the io community
to save the information.