3BUS 208 000 R1301154 Measurement Setup
Enabling APC for Normal Measurement
1. Using the inspect utility, turn on the flag to enable air profile compensation. At
the inspect prompt type:
betaSensor01->airProfileCompOn = 1 (for Basis Weight)
ashSensor01->airProfileCompOn = 1 (for Ash)
caliperSensor01->airProflieCompOn = 1 (for caliper)
topGlossSensor01->airProfileCompOn = 1 ( for Top Gloss)
bottomGlossSensor01->airProfileCompOn = 1 (for bottom Gloss)
optipakSensor01->opacityAirProfileCompOn = 1 AND
optipakSensor01->brightnessAirProfileCompOn = 1 (for OptiPak)
2. If this is to be the normal mode of operation, save the flag settings using the
gstore utility. The frame graph should be saved.