3BUS 208 000 R1301104 Platform Tuning
Operation Overview
When the head is moved off-sheet, a timer is started. When the time accumulation
equals that of the offSheetTime value, the system will set the stdzDelayRequired
flag. If a DIRT standardize request then comes from the host, the standardize request
will be so noted in the stdzRequested flag, but the actual standardize procedure
will be delayed until on-sheet has been requested and the head has been over the
sheet for at least onSheetTime seconds. Note that a single point request will start
the on-sheet timer, but the standardize will not occur until the mode changes back
to scan or off-sheet.