Specifications
PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R1301 83Platform Tuning
Figure 5-7 Head Position Calibration Measurement
8. When requested by the ft utility, enter the measurement taken in Step 7., as
shown in Figure 5-8.
The utility will display the computed value for the distance between the end
column and the measurement window center line, based on the measurement
entered. If the values do not seem reasonable, repeat this step.
Figure 5-8 Head Position Calibration Screen
Home End Column
Measure this distance
Head Package
at Mechanical
Stop
Jog the frame to the HOME limit switch;
PUSH the head against the mechanical stop and
measure the wraparound carriage distance;
Enter the customer units value of this position => 5.25
NOTE: The following measurements are with respect to the head center line
The MEASURED home travel limit is : 17.625000 units
: 1600.000000 counts
The DESIRED home travel limit is : 17.625000 units
Do you wish to repeat the HOME limit setup? (y or n):n
Step 7 - 8