Specifications
PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R130182 Platform Tuning
Figure 5-6 Head Position Calibration – Initial Display (Example)
4. Enter the frame type.
5. After selecting frame type, choose the units to be used for the head position
calibration, as shown in Figure 5-6.
Select 1 for centimeters, or select 2 for inches.
Note: Initially, the Scanning Platform is configured with the customer units
defined as centimeters. If it is necessary to change the customer
units to inches, all of the Scanning Platform dimension variables
must be converted to inches.
6. When requested by ft, use the JOG push buttons to move the Scanning Platform
head package to the home limit switch.
The home side limit switch is activated when the scanning head will not jog
further in the home end column direction.
7. Measure the distance from the home end column to the edge of the carriage
wrap–around assembly as shown in Figure 5-7.
Record the measurement in the customer units chosen in Step 4.
*** HEAD POSITION CALIBRATION ***
The CURRENT head position slope is : 0.010000
The CURRENT head position offset is : 1.725000
The CURRENT scanner home travel limit is: 17.625000
This frame has auto edge of sheet (AEOS):
The FAR edge detector offset is: 19.500000
Please enter the frame type or q to quit;
1 for 700;
2 for 1200 or Dual Rail U-Frame;
3 for Single Rail U-Frame;
Please enter the customer units for head position (1 = cm; 2 = inch; q to quit);2
Step 4
The CURRENT scanner far travel limit is293.075000
The HOME edge detector offset is: 35.000000