Owner manual

Chapter 5 Configuring the PowerSmart Socket PQM
Configuring Billing/TOU
PowerSmart Socket Power Quality Meter 105
Configuring Billing/Tariff Registers
To configure the meter billing/TOU registers, select
Energy/TOU from the Meter Setup menu.
The available options are shown in the following table:
Parameter
Options Default Description
Billing/TOU Registers
TOU Unchecked
Checked
Unchecked Links multi-tariff registers to the selected
energy source
Use Profile Unchecked
Checked
Checked Enables recording energy registers in
monthly/daily billing profile files (both total
and tariff registers if TOU is enabled).
Always enabled for all configured billing
registers.
Dmd Profile Unchecked
Checked
Unchecked Enables recording maximum demand
registers in monthly/daily billing profile files
(both total and tariff registers if TOU is
enabled)
Sum Profile Unchecked
Checked
Checked Enables recording total (summary) registers
in monthly/daily billing profile files. Always
enabled for all configured billing registers.
Units None
kWh+ (delivered)
kWh- (received)
kvarh+ (delivered)
kvarh- (received)
kvarh Q1
kvarh Q2
kvarh Q3
kvarh Q4
kVAh (total)
kVAh+ (delivered)
kVAh- (received)
None The register measurement unit and
quadrants.
Selected automatically for registers linked
to internal energy sources.
Select an appropriate measurement unit for
external pulse sources.