User Manual

Chapter 3 Multi-Mon Display Operations
Menu Operations
Multi-Mon Multiple Circuit Energy Monitor
33
To enter the menu, select the COM1 or COM2 entry from the main menu,
and then press the ENTER button. For instructions on navigating in the
menu, see Viewing and Changing Setup Items.
The following table lists available port options.
Label
LabelLabel
Label
Parameter
ParameterParameter
Parameter
Options
OptionsOptions
Options
Default
DefaultDefault
Default
Description
DescriptionDescription
Description
Protocol
ProtocolProtocol
Protocol
Communication
s protocol
Modbus RTU,
Modbus ASCII
Modbus
RTU
The communications
protocol for the port
Interface
InterfaceInterface
Interface
Port interface RS485
RS485, RS232,
Modem,
Ethernet, RF
COM1
COM2
Not changeable;
automatically detected
by the device
Address
AddressAddress
Address
Device address 1-247 1
Device’s base network
address (see Submeter
Addressing )
Baud rate
Baud rateBaud rate
Baud rate
Baud rate 2.4-115.2 kbps 19.2 kbps The port baud rate
Data/Prty
Data/PrtyData/Prty
Data/Prty
Data format and
parity
7E, 8N, 8E 8N
7E data format should
not be used with the
Modbus RTU protocol
Send Delay
Send DelaySend Delay
Send Delay
Transmission
delay
0-1000 ms 5 ms
The minimum time after
the last request
character is received to
start the transmission.
Chr.Tmout
Chr.TmoutChr.Tmout
Chr.Tmout
Inter-character
timeout
0-1000 ms 4 ms
The maximum time the
line is allowed to idle
before closing a
connection in the
Modbus RTU protocol
NOTE
NOTENOTE
NOTE
When using the ExpertPower
When using the ExpertPowerWhen using the ExpertPower
When using the ExpertPower
client (see
client (see client (see
client (see Configuring eXpertPower Client
Configuring eXpertPower ClientConfiguring eXpertPower Client
Configuring eXpertPower Client),
), ),
),
submeter address
submeter address submeter address
submeter address 99 on the Ethernet port COM2 is reserved for the
99 on the Ethernet port COM2 is reserved for the 99 on the Ethernet port COM2 is reserved for the
99 on the Ethernet port COM2 is reserved for the Multi
MultiMulti
Multi-
--
-
Mon
MonMon
Mon router and must not fall inside the range of the submeter addresses for
router and must not fall inside the range of the submeter addresses for router and must not fall inside the range of the submeter addresses for
router and must not fall inside the range of the submeter addresses for
this port.
this port.this port.
this port.
Local Network Settings
Local Network SettingsLocal Network Settings
Local Network Settings
This menu allows you to configure the Ethernet modem (if present) for direct
communications through the LAN or the Internet.
To enter the menu, select the Net entry from the main menu, and then press
the ENTER button. For instructions on navigating in the menu, see Viewing
and Changing Setup Items.
The following table lists available Ethernet options.
Label
LabelLabel
Label
Default
DefaultDefault
Default
Description
DescriptionDescription
Description
IP Address
IP AddressIP Address
IP Address
192.168.0.203 Device IP address
Subnet Mask
Subnet MaskSubnet Mask
Subnet Mask
255.255.255.0 Subnet mask
Def.Gateway
Def.GatewayDef.Gateway
Def.Gateway
192.168.0.1 Default gateway
Local Settings
Local SettingsLocal Settings
Local Settings
This menu allows you to configure your local time zone settings.
To enter the menu, select the Local entry from the main menu, and then
press the ENTER button. For instructions on navigating in the menu, see
Viewing and Changing Setup Items.
The following table lists available options.
COM1
Exit
COM1
Protocol
Modbus RTU
ENTER
Net
Exit
Net
IP Address
192.168.000.203
ENTER
Local
Exit
Local
Country
Default
ENTER