User Manual
Chapter 3 Multi-Mon Display Operations
Display Views
Multi-Mon Multiple Circuit Energy Monitor
27
Total Energy and Maximum Demand Registers
Total Energy and Maximum Demand RegistersTotal Energy and Maximum Demand Registers
Total Energy and Maximum Demand Registers
Page
Page Page
Page
№
№№
№
Page content
Page contentPage content
Page content
Description
DescriptionDescription
Description
1 Total kWh:
Total kWh:Total kWh:
Total kWh:
124100.0
124100.0 124100.0
124100.0
Total kWh
2 Total kvarh:
Total kvarh:Total kvarh:
Total kvarh:
124.0
124.0 124.0
124.0
Total kvarh
2 Total kVA:
Total kVA:Total kVA:
Total kVA:
124100.0
124100.0 124100.0
124100.0
Total kVAh
3 Max.Dmd kW
Max.Dmd kWMax.Dmd kW
Max.Dmd kW
25.588
25.588 25.588
25.588
Total kW maximum demand
4 Max.Dmd kvar
Max.Dmd kvarMax.Dmd kvar
Max.Dmd kvar
4.709
4.709 4.709
4.709
Total kvar maximum demand
5 Max.Dmd kVA
Max.Dmd kVAMax.Dmd kVA
Max.Dmd kVA
26.017
26.017 26.017
26.017
Total kVA maximum demand
6 Max.Dmd I1, A
Max.Dmd I1, AMax.Dmd I1, A
Max.Dmd I1, A
15.58
15.58 15.58
15.58
Ampere maximum demand
7 Max.
Max.Max.
Max.Dmd I2, A
Dmd I2, ADmd I2, A
Dmd I2, A
15.58
15.58 15.58
15.58
Ampere maximum demand
8 Max.Dmd I3, A
Max.Dmd I3, AMax.Dmd I3, A
Max.Dmd I3, A
15.58
15.58 15.58
15.58
Ampere maximum demand
9 Max.Dmd V1, V
Max.Dmd V1, VMax.Dmd V1, V
Max.Dmd V1, V
120.5
120.5 120.5
120.5
Volt maximum demand
10 Max.Dmd V2, V
Max.Dmd V2, VMax.Dmd V2, V
Max.Dmd V2, V
120.5
120.5 120.5
120.5
Volt maximum demand
11 Max.Dmd V3, V
Max.Dmd V3, VMax.Dmd V3, V
Max.Dmd V3, V
120.5
120.5 120.5
120.5
Volt maximum demand
Service Display
Service DisplayService Display
Service Display
Page
Page Page
Page
№
№№
№
Page content
Page contentPage content
Page content
Description
DescriptionDescription
Description
1 Diagnostics
DiagnosticsDiagnostics
Diagnostics
3
33
3
Device diagnostics. See Diagnostics
Display below.
2 S/N
S/N S/N
S/N 9
99
956456
5645656456
56456
Device serial number
3 S/W V1
S/W V1S/W V1
S/W V18.5.1
8.5.18.5.1
8.5.1
Boot:
Boot: Boot:
Boot: V1.
V1. V1.
V1.2
22
2.
..
.1
11
1
Software version
Boot loader version
4 COM1:
COM1: COM1:
COM1:
A1, Bd19.2
A1, Bd19.2A1, Bd19.2
A1, Bd19.2
COM1 port: address and baud rate
5 COM2: Ethernet
COM2: EthernetCOM2: Ethernet
COM2: Ethernet
192.168.0.203
192.168.0.203192.168.0.203
192.168.0.203
COM2 port: node address and net ID, or
IP address
6 Ph1 Ph2 Ph3
Ph1 Ph2 Ph3Ph1 Ph2 Ph3
Ph1 Ph2 Ph3
I1 I2 I3
I1 I2 I3 I1 I2 I3
I1 I2 I3
Submeter phase current assignments
Di
DiDi
Diagnostics Display
agnostics Displayagnostics Display
agnostics Display
The diagnostics display shows a list of the device diagnostic codes recorded
as a result of the meter self-test diagnostics. The diagnostics page is only
displayed if errors were detected.
See Device Diagnostic Codes in Appendix F for the list of diagnostic codes
and their meanings. See Device Diagnostics in Chapter 2 for more
information on the Multi-Mon built-in diagnostics. See Reset in Chapter 3 on
how to clear the device diagnostics status from the display.
ENTER