User manual
4
4. Cable Diagram
4.1 Function Description of the Turnstile Control Board
If you are using TS2011 or TS2022, all the connections between access control and turnstile control board are done in factory. Just plug
in communication cable to access controller and do the setting.
If you are using TS2000, you need to connect access control system to the turnstile control board, please check the content in this
chapter carefully.
Warning: The third party access control system lock relay trigger time should be 1 second or less than 1 second.
Power supply input
RS485 (Reserved)
opening signal Input
Emergency Switch
Optocoupler Signal
Input
Optocoupler
Power Output
Direction Indicator
Input
Direction Indicator
Input
Passing Indicator
Input
Output end of
counter signal
Input end of drop-
arm electromagnet
Input end of
turnstile opening
Figure 4-1
Interface description:
Opening Signal Input: to receive relay signal and open the turnstile.
Emergency Switch: to keep the turnstile open in case there are fire or other emergencies.
Direction Indicator Output: to connect a LED screen and indicate whether this passage is allowed to pass.
Passing Indicator Output: to connect a LED screen and indicate if user verification is successful and whether it is able to pass.
Counter Output: to connect a LED screen and display the number of people passed that is generated by the push of tripod arms, each
completed push means pass one time.
Drop Arm Electromagnet Output: to control the tripod arms manually rise up and automatically drop down.
4.2 Connection Diagram of the Access Control Panel or Standalone Access Control Device
Enter
Exit
Access Control
Turnstile Control Board
Counter Output Port
Opening Signal Input Port
SEN
GND
BUT
NO1
COM1
NC1
COM2
NO2
COM1
NO1
K1
GND
K2
GND
Figure 4-2
Notes:
1. The Counter is an optional accessory.
2. The lock driving duration of the access control panel or standalone
access control device needs to be set to 1s or 0s, and the door sensor
needs to be set to “None”.