Specifications
Operation
3.6 Using Trigger Input and Output
It is possible to trigger external devices and to send start/stop signals to the
wave generators with the digital I/O lines of the E-517. See
"Digital In/Out
Socket"
(p. 71) for the lines and pinout. With the E-517, there is a fixed
one-to-one assignment of axes to digital output and input lines. This means
that:
■ With E-517.i1 models only the DIO_O1 and DIO_I1 lines are
available
■ If axes / channels are deactivated (see "Configure Axes and
Channels" in the E-517 User Manual for details), only the output and
input lines of the active axes are available
You can ask for the available lines with the TIO? command.
You can program the DIO_O1 to DIO_O3 output lines (TTL, active high) to
trigger other devices. Programming can be done using the CTO command.
If the trigger output is to be synchronized with the wave generator output,
you can use CTO in combination with
■ TWS which defines trigger action for certain waveform points
■ Certain WGO options which start the wave generator and the
corresponding trigger output
See "Configuring Trigger Output" and "Trigger Output Synchronized with
Wave Generator" in the E-517 User Manual for examples.
The DIO_I1 to DIO_I3 input lines (TTL, active high) can be used in
conjunction with the WGO command to start and synchronize the wave
generator output. See "Wave Generator Started by Trigger Input" in the
E-517 User Manual for an example.
www.pi.ws E-517 PZ214Equ Release 1.0.0 Page 35