Specifications
Operation
Command
String to Send
Response Action Performed
SVA? A A=+0085.0000
Query the commanded output voltage. It
resulted from the last valid SVA command.
ERR? 302 -
(error 302 -
"Voltage out
of limits")
Get error code of the last occurred error. The
error code is cleared by the ERR? command
ERR? 0 - (error 0
- "No error")
No error occurred since the last ERR? query
VMA A 100
Set voltage output high limit for the axis to 100
volts.
SVA A 100
Set the output voltage for axis A to 100 volts.
SVA? A A=+0100.0000
Query the commanded output voltage. It
resulted from the last valid SVA command.
VOL? 1 1=+0099.3135
Query the current output voltage of piezo
channel 1.
POS? A A=+0106.1647
Query the current position axis A. The nominal
travel range @ 0 to 100 V is 100 µm, with a
tolerance of ±20%.
SVR A -20
Move axis A relative by subtracting 20 volts
from the current output voltage.
VOL? 1 1=+0080.4106
Query the current output voltage of piezo
channel 1.
POS? A A=+0093.9297
Query the current position axis A.
Example 2:
This example moves three axes in closed-loop operation. Afterwards the
current position is queried. It is discovered that axis B is blocked by an
external hard stop. It will then be moved back to its zero position.
Hardware: E-500 system with 3 channels, each equipped with a sensor
servo-module, piezo stage with 3 axes
www.pi.ws E-517 PZ214Equ Release 1.0.0 Page 29