Specifications

Operation
CHANNEL SETTING, where you can command motion (in ONLINE
mode) or the check current position and voltage (in OFFLINE mode)
for individual channels. See
"Trackball Functions" (p. 22) for details
You can configure the position and voltage display via parameters (e.g.
show / hide channels, set the number of digits). See "Activate/Deactivate
Axes and Channels" in the E-517 User Manual for more information.
3.1.3 Trackball Functions
You can operate the trackball on the E-517 front panel by pressing it or
rolling it left/right or up/down with your fingers. It gives access to the
following functionality:
Display screen selection:
You can select the active
display screen (p. 21) by rolling the
trackball to the left or to the right. After power-on or reboot, always
the "main screen" is active (all channels displayed)
ONLINE/OFFLINE setting:
When the "main screen" is active, you can switch between ONLINE
and OFFLINE mode for all channels by pressing the trackball (see
"Modes of Operation" (p. 23) for details)
Skipping start-up macro:
To skip the execution of the start-up macro, press the trackball once
immediately after you have powered on or rebooted the piezo control
electronics (while "Physik Instrumente" is still shown on the display).
For details about start-up macro definition, see
"Start-Up Macro"
(p.
40)
E-517 configuration:
On the DISPLAY SERVICE and COMMUNICATION screens you can
use the trackball to access and modify several settings. See
"Display
Screens"
(p. 21) for details
Commanding motion in ONLINE mode:
The CHANNEL SETTING screen gives access to channel-specific
screens. There you can enter target values (position or voltage,
depending on the current servo mode) to move the corresponding
axis. Rolling the trackball left/right selects the digit to be changed,
rolling the trackball up/down selects the value for that digit. You can
switch between the individual channels by pressing the trackball.
While trackball settings and move commands can be used in parallel
to command axis motion, they are not accepted when the wave
generator is running for the axis. See "Control Value Generation" in
the E-517 User Manual for more information.