Specifications

First Steps
to copy the values of protected parameters from the Edit Mask
column to the controller, enter the password "advanced" to switch
to command level 1.
See the PIMikroMove™ Manual for further information.
2.3 Quick Start
The following instructions illustrate the first steps with the E-517 using
PIMikroMove™ because that software offers a convenient user interface for
operating the system. See the PIMikroMove™ Manual for the complete,
more-detailed software description and
"Installing the Software on the Host
PC"
(p. 11) for how to install the program. In the example below, an
E-517.i3 3-channel model and an X-Y-Z stage are used.
!
CAUTION
Thermally stable systems have the best performance. For a thermally
stable system, power on the E-517 at least one hour before you start
working with it.
!
CAUTION
If the piezo stage starts oscillating (humming noise):
In closed-loop operation, switch off the servo immediately. The load
and / or the dynamics of operation probably differ too much from the
setup for which the system was calibrated.
In open-loop operation, stop the motion immediately. Do not operate
the piezo stage at its resonant frequency because the notch filter(s)
may be deactivated in open-loop operation. You can measure the
resonant frequency using PIMikroMove™; see "Data Recorder" (p. 31)
for more information.
Otherwise the piezo stage could be irreparable damaged.
Re-calibration should only be done by adequate trained personnel and
after consultation with PI. Otherwise preset data will be lost.
1 Interconnect your system. Find details in the User manual of the
analog piezo control electronics in which the E-517 is integrated,
and in
"Communication" (p. 45) and "Using Trigger Input and
Output
" (p. 35).
2 Power on the system. Find details in a dedicated section (p. 31).
www.pi.ws E-517 PZ214Equ Release 1.0.0 Page 13