Specifications
First Steps
program.
Proceed as follows to create a parameter file:
1 Power on the system. Find details in a
dedicated section (p. 31).
2 Start PIMikroMove™ on the host PC and establish a connection to
the E-517 as described in
"Quick Start" (p. 13).
3 In the PIMikroMove™ main window, open the Device Parameter
Configuration window using the E-517 ⇒ Parameter Configuration
menu sequence.
4 In the Device Parameter Configuration window, save the controller
parameters to a file. Use the
Save or Save As buttons in the top
left-hand corner of the window, or use the File ⇒ Save Edit Values
or File ⇒ Save Edit Values As menu sequences. In fact, the values
from the
Edit Mask column are saved.
In the Device Parameter Configuration window of PIMikroMove™, proceed
as follows to load back the content of a parameter file (with the extension
.pam):
1 Use the File ⇒ Load and select menu sequence. The loaded
parameter values are written in the corresponding
Edit Mask fields.
2 You can copy the loaded parameter values from the
Edit Mask
fields to the RAM (volatile memory) or non-volatile memory of your
controller using the three
Write selected edit values... buttons in the
top right-hand corner of the window.
Note that depending on the controller, changing parameters may
require a certain command control level (CCL). You can switch to
command level 1 and change level-1 parameters (see
CCL
column), while command levels >1 are reserved for service
personnel. In the dialog which pops up automatically when you try
www.pi.ws E-517 PZ214Equ Release 1.0.0 Page 12